*Applicable and Description
1. Applicable Scope HLC-1NU04GG(1P/40A/208-240VAC) Definite Purpose Contactor(Follow Defers To DP Contactor),Mainly Is Suitable For 50Hz Or 60Hz, When The AC-8a Use Category Fixed Working Voltage Is 240V Or 277V The Nominal Current Up To The 40A Electric Circuit, Is Suitable For The Starting And The Control Single-Phase Motor (Or Compressor) And Other Single-Phase Loads.Mainly Uses In The Domestic Electric Appliances Profession, Specially In Air Conditioning Profession,Conforms To IEC60947, UL508 and GB14048standard. |
2.Type and Meaning
|
HL | C | – | 1N | U | 04 | GG | |
Company Code | Contactor | Packing Y : Individual Box Pack – : Factory Bulk Pack | Pole: One Pole without Shunt | Coil Voltage | Rating of current | Terminal |
*Product Explanation And Main Technical Parameter
Type | HLC-1NU04GG(1P/40A/208-240VAC) Definite Purpose Contactor | |
Standard | IEC60947 | UL508 |
Rating of Current | Ie 40A | FLA: 40A |
Resistive Amps | Ith 50A | RES: 50A |
Rating of Contacts Voltage | Ue 240/277V | 240/277/480/600VAC |
Rating of Insulation Voltage | Ui 660V | 600V |
Rating of Coil Voltage | Us 280-240V | Us: 208-240VAC 50/60Hz |
Mechanical Life | 1000,000 Cycle | 1000,000 Cycle |
Electricity life | 100,000 Cycle | 250,000 Cycle |
Product Explanation |
1.Product Description HLC-1NU04GG(1P/40A/120VAC) Is Suitable To Exchanges 50 Or 60hz, Fixed Working Voltage To 240v or 277v, Fixed Operating Current To 40A Single-Phase Load Circuit Control,At Present, Widely Applies To The Single-Phase Mechanical Device Main Circuit As Well As The Single-Phase Air-Conditioner Compressor Control. 2 .The Regular Service Conditon And Installs The Condition 3 .Main Technical Parameter 4 . Installing Specification And Install Size a. Installs The Way To Be Fixed For The Screw, Some Two Kinds Install The Size To Choose One Kind Of Size Fitting Surface And The Horizontal Plane Are The Vertical Shape Gradient Are Not Bigger Than ±5° b. Before The Use Should Inspect The Power Terminal And The Contactor
|
|
|
*Conforms To The Standard
Conforms To National Standard And International Standard
|
1 Conforms To UL508, IEC60947, GB14048Standard |
2 Approved By UL,CUL,TUV,CE,CCC,Safe Certification and ISO9001 System Certification(SGS) | |
CCC Certificate Number: 2005010309156761 UL Files Number: E251539 |
*Ordering Request
In Order To Guarantee You Purchase Right, Please Read The Specify Type Before Order.
Contactor Specification Model, Pole Number, Coil Control Voltage, Rating Of Operating Current, Wiring Way(Terminal), Whether With Cover ,The Packing Way, Etc
If You Request As Follows: Nominal Current: 40A, Working Voltage: 240/277V,480V,600V, Pole Number: One Pole Without Shunt, Coil Control Voltage:24V, Wiring Way: Quick Connect, Load Current: Single-Phase Motor Controls Or Heating Load, Packing: 50/Each Box (Factory Packing), With The Cover. Then You May Be Elect The Type : HLC-1NU04GG |
Lifts The Samples As Follows (Contains Derivation Type From This Model)
Rating of Current
Ie |
Pole | Rating of Coil Control Voltage | Control Motor Power | ||||
24VAC | 120VAC | 208/240VAC | 277VAC | 380/480VAC | 240VAC | ||
40A |
1P |
HLC-1NQ04GG | HLC-1NT04GG | HLC-1NU04GG | HLC-1NV04GG | HLC-1NW04GG | 2.5Kw |
Peso | 0.3 kg |
---|
Valoraciones